Ideal Product Categories

About Us

cable, vdsl, patch

 

Hyperline- Ideal Industries Cutters - Coax/Twisted Pair Cutters - Twisted Pair Cutters - Coax Cutters - Fiber Cutters Fiber Optic Test Equipment- Ideal Industries


American Tech Supply is now an authorized Hyperline distributor

From copper to fiber, the Hyperline system of products includes everything you need for installation, termination, testing and troubleshooting. And our level of technical expertise, training and customer support ensures that your total cost of ownership is kept to a minimum.

Shielded twisted pair cable (STP), category 6 (300 MHz), 4 pairs, stranded (patch), 26AWG

Shielded twisted pair cable (STP), category 6 (300 MHz), 4 pairs, stranded (patch), 26AWG
1 – Jacket
2 – Shield-foil
3 – Twisted pairs stranded (patch)

Specifications:
Meets ANSI/EIA/TIA 568-B.2-1 requirements
Fire protection – CM
The cable meets UL 1581 VW-1 fire safety standard

Description:
Shielded Copper cable, 4 pairs, category 6, stranded (patch)
4 separately foil-shielded pairs
Cable is used for indoor installation

Materials:
Conductive material: wire made of soft annealed electrolytic copper
Conductor insulation: HDPE, film-porous-film structure
The cable jacket: PVC
Shield: every pair is separately shielded with polyester aluminum foil, which covers 100% of twisted pair

Technical characteristics:
Conductor diameter: 7 x 0.16 mm (7 x 0.006") (26 AWG)
Insulated conductor diameter: 0.98 mm (0.038")
Outer cable diameter: 5.9 mm (0.23")
Jacket thickness: 0.4 mm (0.015")
Minimum bend radius: 8 outer cable diameters
Conductor elongation: 14% minimum
Operating temperature: -5°C – +60°C (+23°F – +140°F)
Weight per 1000 ft (304.8 m): 12.2 kg (26.9 lbs)
Standard package: 500 m (1640 ft)

Electrical characteristics:
Frequency, MHz Pair attenuation, dB/100m (dB/100ft) NEXT losses, dB RL, dB
1 2.8 (0.85) 85 20
4 5.4 (1.6) 85 23
10 8.6 (2.62) 85 26
16 10.7 (3.26) 85 26
31.25 14.8 (4.51) 85 24
62.5 21.5 (6.55) 80 22
100 28 (8.53) 80 20
200 40.5 (12.3) 80 17.5
300 50.5 (15.39) 75 16


Maximum conductor resistance at 20°C (68°F) 145 Ohm/km (233.35 Ohm/mile)
Resistance unbalance 2% max.
Resistance at the frequency of 1-600 MHz 100 ± 15 Ohm
Transfer impedance at the frequency of 1-10 MHz 10 MOhm/m (3.05 MOhm/ft) max.
Insulation resistance at 20°C (68°F) 5 GOhm/km (8.05 GOhm/mile) min.
Capacitive unbalance at 1 kHz relative to earth 1.5 pF/m (0.46 pF/ft) max.
Maximal voltage 30 V RMS
Dielectric power 700 V/1min
Propagation velocity 79-80%
Max. derivation of propagation delay at the frequency of 1 MHz 5.7 ns/m (1.74 ns/ft)
Max. derivation of propagation delay at the frequency of 10 MHz 5.4 ns/m (1.64 ns/ft)
Max. derivation of propagation delay at the frequency of 100 MHz 5.3 ns/m (1.61 ns/m)
Max. derivation of propagation delay at the frequency of 1-600 MHz 30 ns/100 m (9.14 ns/100 ft)

Ordering:
STP4-C6-PATCH-INDOOR Shielded twisted pair cable (STP), category 6 (300 MHz), 4 pairs, stranded (patch), 26AWG

Call (866) 342-3721 Or Click On The Chat Button At The Top Of The Page To Talk To One Of Our Representatives

 

 

 

 

 

 

 