Product Categories

About Us

cable, vdsl, patch

 

Signamax- Signamax 0651800- 10/100 to 100FX Industrial DIN-Rail Mount Media Converters- Signamax Industrial Ethernet- Media Converters- Ethernet Switches- Industrial DIN-rail Mount Power Supplies



10/100 to 100FX Industrial DIN-Rail Mount Media Converters
Signamax Connectivity Systems' 065-1800 series 10/100 to 100BaseFX have been developed to operate in harsh industrial environ-ments that require ruggedized equipment that can operate in severe temperature extremes. These media converters are an afford-able solution for outdoor environments, transportation roadside systems, shop floors, and other harsh environments where consistent operation at temperature extremes of -40°F to 176°F (-40°C to 80°C) is necessary. These media converters are compact, plug-and-play devices that do not require complex user setup, but also have the manual setting features necessary to adjust to unusual oper-ating conditions.

SPECIFICATIONS :

* APPLICABLE STANDARDS

IEEE802.3 10BaseT
IEEE802.3u 100BaseTX / 100BaseFX
IEEE802.3x Flow Control and Back pressure

* FIXED PORTS

1 twisted-pair port meeting IEEE 802.3 10BaseT & IEEE 802.3u 100BaseTX standard specifications, Auto MDI/MDI-X and Auto-Negotiation Function supported (all models)
PLUS
1 100Base FX port meeting IEEE 802.3u 100BaseFX standard specifications with ST/MM, 2 km span (Model 065-1800TB)
OR
1 100Base FX port meeting IEEE 802.3u 100BaseFX standard specifications with SC/MM, 2 km span (Model 065-1810TB)
OR
1 100Base FX port meeting IEEE 802.3u 100BaseFX standard specifications with SC/SM, 20 km span (Model 065-1820TB)
OR
1 100Base FX port meeting IEEE 802.3u 100BaseFX standard specifications with SC/SM, 40 km span (Model 065-1820EDTB)
OR
1 100Base FX port meeting IEEE 802.3u 100BaseFX standard specifications with SC/SM, 75 km span (Model 065-1820XLDTB)
OR
1 100Base FX port meeting IEEE 802.3u 100BaseFX standard specifications with WDM A SC/SM simplex, 20 km span (Model 065-1876ATB)
OR
1 100Base FX port meeting IEEE 802.3u 100BaseFX standard specifications with WDM B SC/SM simplex, 20 km span (Model 065-1876BTB)
OR
1 100Base FX port meeting IEEE 802.3u 100BaseFX standard specifications with WDM A SC/SM simplex, 40 km span (Model 065-1876AEDTB)
OR
1 100Base FX port meeting IEEE 802.3u 100BaseFX standard specifications with WDM B SC/SM simplex, 40 km span (Model 065-1876BEDTB)

* TWISTED-PAIR CABLE REQUIREMENTS

Category 5 or better cable, 100 meters maximum distance for 100BaseTX; Category 3 or better cable, 100 meters maximum distance for 10BaseT

* LED STATUS INDICATORS

Per Unit: Power1 (Green), Power2 (Green). Fault, LFS
Per Port: 10/100BaseT/TX port: 100 Mbps Speed, Link/Activity, FDX/COL
100BaseFX port - Link/Activity, FDX/COL

* PERFORMANCE

Latency: < 4.2 µs (LIFO)
Throughput @ 100Base: 148,810 pps (64-byte packets)

* SWITCH ARCHITECTURE

Store and Forward

* FIBER INTERFACE, MULTIMODE MODELS

Type: LED
Wavelength: 1300 nm nominal (1270 nm maximum, 1380 nm minimum)
Maximum Output Power: - 14.0 dBm
Minimum Output Power: - 20.0 dBm
Sensitivity: - 33.0 dBm
Maximum Input Power: - 8.0 dBm
Link Power Budget: 13.0 dB

* FIBER INTERFACE, SINGLEMODE PN 065-1820TB

Type: MQW Laser
Wavelength: 1300 nm nominal (1260 nm maximum, 1360 nm minimum)
Maximum Output Power: - 7.0 dBm
Minimum Output Power: - 15.0 dBm
Sensitivity: - 34.0 dBm
Maximum Input Power: - 7.0 dBm
Link Power Budget: 19.0 dB

* FIBER INTERFACE, SINGLEMODE PN 065-1820EDTB

Type: MQW Laser
Wavelength: 1300 nm nominal (1261 nm maximum, 1360 nm minimum)
Maximum Output Power: - 5.0 dBm
Minimum Output Power: - 12.0 dBm
Sensitivity: - 35.0 dBm
Maximum Input Power: - 5.0 dBm
Link Power Budget: 23.0 dB

* FIBER INTERFACE, SINGLEMODE PN 065-1820XLDTB

Type: MQW Laser
Wavelength: 1300 nm nominal (1270 nm maximum, 1350 nm minimum)
Maximum Output Power: + 3.0 dBm
Minimum Output Power: - 3.0 dBm
Sensitivity: - 37.0 dBm
Maximum Input Power: - 0.0 dBm
Link Power Budget: 34.0 dB

* FIBER INTERFACE, SINGLEMODE PN 065-1876ATB

Type: MQW Laser
Transmit Wavelength: 1310 nm nominal (1260 nm maximum, 1360 nm minimum)
Receive Wavelength: 1550 nm nominal (1480 nm maximum, 1600 nm minimum)
Maximum Output Power: - 8.0 dBm
Minimum Output Power: - 14.0 dBm
Sensitivity: - 33.0 dBm
Maximum Input Power: - 3.0 dBm
Link Power Budget: 19.0 dB

* FIBER INTERFACE, SINGLEMODE PN 065-1876BTB

Type: MQW Laser
Transmit Wavelength: 1550 nm nominal (1480 nm maximum, 1580 nm minimum)
Receive Wavelength: 1310 nm nominal (1260 nm maximum, 1360 nm minimum)
Maximum Output Power: - 8.0 dBm
Minimum Output Power: - 14.0 dBm
Sensitivity: - 33.0 dBm
Maximum Input Power: - 3.0 dBm
Link Power Budget: 19.0 dB

* FIBER INTERFACE, SINGLEMODE PN 065-1876AEDTB

Type: MQW Laser
Transmit Wavelength: 1310 nm nominal (1260 nm maximum, 1360 nm minimum)
Receive Wavelength: 1550 nm nominal (1490 nm maximum, 1600 nm minimum)
Maximum Output Power: - 3.0 dBm
Minimum Output Power: - 8.0 dBm
Sensitivity: - 33.0 dBm
Maximum Input Power: - 3.0 dBm
Link Power Budget: 25.0 dB

* FIBER INTERFACE, SINGLEMODE PN 065-1876BEDTB

Type: MQW Laser
Transmit Wavelength: 1550 nm nominal (1480 nm maximum, 1580 nm minimum)
Receive Wavelength: 1310 nm nominal (1260 nm maximum, 1360 nm minimum)
Maximum Output Power: - 3.0 dBm
Minimum Output Power: - 8.0 dBm
Sensitivity: - 33.0 dBm
Maximum Input Power: - 3.0 dBm
Link Power Budget: 25.0 dB

* POWER INPUT REQUIREMENTS

Redundant 12 to 48 Volts DC Terminal Block

* PHYSICAL CHARACTERISTICS

Dimensions: 1.97 in. x 5.35 in. x 4.33 in., W x H x D (50 mm x 136 mm x 110 mm)
Housing: IP-30 protection, metal case
Weight: 1.76 lb (0.8 kg.)

* CERTIFICATIONS

NEMA TS1/2 Environmental requirements for traffic control equipment
ISO: Manufactured in an ISO9001 facility

Environmental Test Compliance:
Vibration Resistance (IEC 60068-2-6): 5G@150Hz; Criterion 3
Operation/Storage/Transport Shock (IEC 60068-2-27):
25G @ 11ms (Half-Sine Shock Pulse; Operation)
50G @ 11ms (Half-Sine Shock Pulse: Storage/Transport)
Free Fall (IEC 60068-2-32): Free Fall: 1M (3.281 ft.)

ESD Standards (IEC 61000-4-2):
Enclosure Contact: +/- 4kV; Criteria B
Enclosure Air: +/- 8kV; Criteria B

Radiated FRI Standards (IEC 61000-4-3):
Enclosure Ports: +/- 4kV @ 2.5kHz; Criteria B

Burst Standards (IEC 61000-4-4):
Enclosure Ports: 10V/m, 80 to 1000MHz; Criteria A
D.C. Power Ports: +/- 4kV; Criteria B
A.C. Power Ports: +/- 4kV; Criteria B

Surge Standards (IEC 61000-4-5):
Signal Ports: +/- 1kV Line-to-earth; Criteria B
D.C. Power Ports: +/- 0.5kV Line-to-earth; Criteria B
A.C. Power Ports: +/- 2kV; Line-to-earth; Criteria B

Induced RFI Standards (IEC 61000-4-6):
Signal Ports: 10v@ 0.15 - 80 MHz; Criteria A
DC Power Ports: 10v@ 0.15 - 80 MHz; Criteria A
AC Power Ports: 10v@ 0.15 - 80 MHz; Criteria A
Earth Ground Ports: 10v@ 0.15 - 80 MHz; Criteria A

Magnetic Field Standards (IEC 61000-4-8):
Enclosure Ports: 30A/m@ 50, 60Hz; Criteria A

Voltage Dip Standards (IEC 61000-4-11):
AC Power Ports: 30% Reduction for 0.5 period; Criteria B

* ENVIRONMENT

Operating Temperature: -40°F to 176°F (-40°C to 80°C)
Storage Temperature: -50°F to 200°F (-45°C to 93°C)
Operating Humidity: 10 to 95% (non-condensing)

* INSTALLATION

DIN Rail Kit, or wall mounting ears for 3-way installation

* EMISSIONS

FCC: Part 15 Class A
CE: EN55022 (CISR22 Class A), EN55024 (CISPR24 Class A), CE EN-6100-4-4,
CE EN6100-4-5, CE EN6100-4-6

* SAFETY

UL 1604: Classified for ITE Equipment for use in hazardous locations:
Class 1, Division 2 group A, B, C, & D: Temp Code T4A; -25C < Tamb < 74C
UL 60950, EN 60950, IEC 60950, IEC 61000-6-2

* WARRANTY

Lifetime

10/100 To 100FX DIN-Rail Hardened Media Converters

Part Number

Description

065-1800TB 10/100BaseT/TX to 100BaseFX Industrial Hardened Media Converter,
ST Multimode, 2 km Span, 24 V DC Redundant Power Terminal Block

065-1810TB

10/100BaseT/TX to 100BaseFX Industrial Hardened Media Converter,
SC Multimode, 2 km Span, 24 V DC Redundant Power Terminal Block

065-1820TB

10/100BaseT/TX to 100BaseFX Industrial Hardened Media Converter,
SC Singlemode, 15 km Span, 24 V DC Redundant Power Terminal Block

065-1820EDTB

10/100BaseT/TX to 100BaseFX Industrial Hardened Media Converter,
SC Singlemode, 40 km Span, 24 V DC Redundant Power Terminal Block

065-1820XLDTB

10/100BaseT/TX to 100BaseFX Industrial Hardened Media Converter,
SC Singlemode, 75 km Span, 24 V DC Redundant Power Terminal Block


10/100 To 100FX WDM DIN-Rail Mount Hardened Media Converters

065-1876ATB

10/100BaseT/TX to 100BaseFX Industrial Hardened Media Converter,
Single Fiber SC Simplex Singlemode, Tx=1310 nm; Rx=1550 nm,
20 km Span, 24 V DC Redundant Power Terminal Block

065-1876BTB

10/100BaseT/TX to 100BaseFX Industrial Hardened Media Converter,
Single Fiber SC Simplex Singlemode, Tx=1550 nm; Rx=1310 nm,
20 km Span, 24 V DC Redundant Power Terminal Block

065-1876AEDTB

10/100BaseT/TX to 100BaseFX Industrial Hardened Media Converter,
Single Fiber SC Simplex Singlemode, Tx=1310 nm; Rx=1550 nm,
40 km Span, 24 V DC Redundant Power Terminal Block

065-1876BEDTB

10/100BaseT/TX to 100BaseFX Industrial Hardened Media Converter,
Single Fiber SC Simplex Singlemode, Tx=1550 nm; Rx=1310 nm,
40 km Span, 24 V DC Redundant Power Terminal Block


Industrial Media Converters


Industrial Ethernet


Signamax Connectivity Systems' Industrial Ethernet products provide a cost-effective answer for both media conversion and Ethernet switching needs found in harsh industrial and extreme temperature environments. Whether the need is for physically ruggedized equipment or equipment that can operate in severe temperature extremes, Signamax Network Connectivity products provide the quality needed to get the job done. Signamax managed and unmanaged Ethernet switching and media conversion products are an affordable solution for outdoor environments, transportation roadside systems, shop floors, and other extreme environments where consistent operation at temperature extremes of -40°F to 167°F (-40°C to 75°C) is necessary. 
 

 

 

 

 

 

Network Connectivity

Media Converters Media Converters
Ethernet Switches Ethernet Switches
Industrial Ethernet Industrial Ethernet
SFP Interface Modules SFP Interface Modules
Optical Fiber NICs Optical Fiber NICs

Premise Connectivity

Work Area   Outlet Systems Work Area Outlet Systems
Patching Systems Patching Systems
Cross-Connect Systems Cross-Connect Systems
Patch   CordsPatch Cords
Optical Fiber Systems Optical Fiber Systems
Support Structures Support Structures

 

BIF-Bend Insensitive Fiber

New Bend Insensitive Fiber Jumpers

Raceway Systems- Cable Tray